UV/IR & IR3 Flame Detectors
UV/IR Flame Detector is a combination of a UV- and IR- flame detector which utilizes a microprocessor for electronic signal analysis as both UV and the IR sensor must both exceed their alarm threshold to initiate a fire alarm.
UV/IR Flame Detector has good false alarms rejection capabilities because the UV and the IR sensor do not share false alarm sources.
The triple IR (IR3) flame detector uses an additional alarm criterion: the analysis of the flame flicker-frequency. The infrared IR3 flame detector has good false alarm rejection capabilities.
PRODUCT SPECIFICATIONS UV/IR FLAME DETECTOR
- Sensitive to virtually all fires including Hydrogen Flames
- Resistant to artificial- and sunlight
- Automatic sensor test
- Suitable for indoor and outdoor applications
- Operating temp.: -40 to +70°C (in Safe Area’s only)
- GRP housing
- Relay output for Alarm and Fault
- Sinking 4-20 mA output (stepped)
- CPR-EN54-10 certified
- FM class 3260 Approved
- ATEX certified: II 3G Ex nA IIC T4 Gc, II 3D Ex tc IIIC T 71°C Dc IP65, ambient temp.: -25° to +70°C
- cFMus class 3611 (Nonincendive, Class I, II and III, Div 2), ambient temp.: -25° to +70°C
- California State Fire Marshal (CSFM) listed
PRODUCT SPECIFICATIONS INFRARED IR3 FLAME DETECTOR
- Suitable for heavy- and light Hydrocarbons such as Gasoline, Diesel, Methanol and Ethanol
- The IR3 flame detector is resistant to artificial- and sunlight
- Automatic sensor test
- IR3 flame detectors are suitable for indoor and outdoor applications
- Operating temp.: -40 to +70°C (in Safe Area’s only)
- GRP housing
- Relay output for Alarm and Fault
- Sinking 4-20 mA output (stepped)
- CPR/EN54-10 certified
- FM class 3260 approved
- ATEX certified: II 3G Ex nA IIC T4 Gc, II 3D Ex tc IIIC T 71°C Dc IP65, ambient temp.: -25° to +70°C
- cFMus class 3611 (Nonincendive, Class I, II and III, Div 2), ambient temp.: -25° to +70°C
- California State Fire Marshal (CSFM) listed
CERTIFICATES
UV/IR & IR3 Flame Detectors
UV/IR Flame Detector is a combination of a UV- and IR- flame detector which utilizes a microprocessor for electronic signal analysis as both UV and the IR sensor must both exceed their alarm threshold to initiate a fire alarm.
UV/IR Flame Detector has good false alarms rejection capabilities because the UV and the IR sensor do not share false alarm sources.
The triple IR (IR3) flame detector uses an additional alarm criterion: the analysis of the flame flicker-frequency. The infrared IR3 flame detector has good false alarm rejection capabilities.
PRODUCT SPECIFICATIONS UV/IR FLAME DETECTOR
- Sensitive to virtually all fires including Hydrogen Flames
- Resistant to artificial- and sunlight
- Automatic sensor test
- Suitable for indoor and outdoor applications
- Operating temp.: -40 to +70°C (in Safe Area’s only)
- GRP housing
- Relay output for Alarm and Fault
- Sinking 4-20 mA output (stepped)
- CPR-EN54-10 certified
- FM class 3260 Approved
- ATEX certified: II 3G Ex nA IIC T4 Gc, II 3D Ex tc IIIC T 71°C Dc IP65, ambient temp.: -25° to +70°C
- cFMus class 3611 (Nonincendive, Class I, II and III, Div 2), ambient temp.: -25° to +70°C
- California State Fire Marshal (CSFM) listed
PRODUCT SPECIFICATIONS INFRARED IR3 FLAME DETECTOR
- Suitable for heavy- and light Hydrocarbons such as Gasoline, Diesel, Methanol and Ethanol
- The IR3 flame detector is resistant to artificial- and sunlight
- Automatic sensor test
- IR3 flame detectors are suitable for indoor and outdoor applications
- Operating temp.: -40 to +70°C (in Safe Area’s only)
- GRP housing
- Relay output for Alarm and Fault
- Sinking 4-20 mA output (stepped)
- CPR/EN54-10 certified
- FM class 3260 approved
- ATEX certified: II 3G Ex nA IIC T4 Gc, II 3D Ex tc IIIC T 71°C Dc IP65, ambient temp.: -25° to +70°C
- cFMus class 3611 (Nonincendive, Class I, II and III, Div 2), ambient temp.: -25° to +70°C
- California State Fire Marshal (CSFM) listed